← Dashboard
Return-to-service requires mechanic, station manager, or admin.Start pre-use inspection
PBS-501 · Passenger Boarding Stairs
Out of serviceSelf-propelled passenger stairs
QR-A0006
- Asset Number
- ORD-PBS-0501
- Manufacturer
- Aviogei
- Model
- PSP-200
- Motorized
- Motorized
- Station
- ORD
- Department / LOB
- Ramp
- Last Inspected
- May 07, 2026, 08:20 AM
- Inspected By
- Maria Lopez
- OOS Since
- May 07, 2026, 08:20 AM
- OOS Duration
- 6d 18h
- Last Known Location
- 41.9760, -87.9070
Inspection history
1 record| Date / time | Result | Inspected by | GPS | Signature | Failed items | Notes |
|---|---|---|---|---|---|---|
| May 07, 2026, 08:20 AM | Fail | U001 · #E10001 | 41.9760, -87.9070 | ✓ | 1 | Brake pedal soft on the left side, would not hold on incline. |
Defect history
1 recordOpen OOSDefect is open and the asset is currently out of service.
- D-0001Do the brakes function correctly?Service brake pressure failure on left side; unit cannot hold on incline.OOS since May 07, 2026, 08:20 AM6d 18h (and counting)
- OOS location
- 41.9760, -87.9070
- Source inspection
- I-0001