ASIP
GSE Readiness · MVP
← Dashboard
Return-to-service requires mechanic, station manager, or admin.Start pre-use inspection

PBS-501 · Passenger Boarding Stairs

Out of service

Self-propelled passenger stairs

QR-A0006
Asset Number
ORD-PBS-0501
Manufacturer
Aviogei
Model
PSP-200
Motorized
Motorized
Station
ORD
Department / LOB
Ramp
Last Inspected
May 07, 2026, 08:20 AM
Inspected By
Maria Lopez
OOS Since
May 07, 2026, 08:20 AM
OOS Duration
6d 18h
Last Known Location
41.9760, -87.9070

Inspection history

1 record
Date / timeResultInspected byGPSSignatureFailed itemsNotes
May 07, 2026, 08:20 AMFailU001 · #E1000141.9760, -87.90701Brake pedal soft on the left side, would not hold on incline.

Defect history

1 record
Open OOSDefect is open and the asset is currently out of service.
  • D-0001Do the brakes function correctly?
    Service brake pressure failure on left side; unit cannot hold on incline.
    OOS since May 07, 2026, 08:20 AM
    6d 18h (and counting)
    OOS location
    41.9760, -87.9070
    Source inspection
    I-0001